<ErrorNumber>22116</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Measured Main Scan Size (%d.%d\") larger than maximum allowable size
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If the machine is refusing to accept the correct size plates, check on the
configuration (50x67 vs 52x80) via the following paramters:
sys maxssz - Password protected encoded value for the subscan size of the machine
config msz - Should be set to value to match the customers machine type (ie. 50 or 52)
config ssz - Same as msz but for ThermoFlex acceptable values are 67 or 80
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Re-submit with an acceptable sized plate.
If plate dimensions are already within the maximums for your ThermoFlex then
contact Creo Service.
</text></DescriptionText>
</OperatorAction>
<Cause>
The plate loaded is larger than the largest plate acceptable on the machine.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_maxssz.xml</LinkAddress><LinkTitle>NVS: sys maxssz</LinkTitle></Link>
<Link><LinkAddress>../nvs/config_cfg_msz.xml</LinkAddress><LinkTitle>NVS: config msz</LinkTitle></Link>
<Link><LinkAddress>../nvs/config_cfg_ssz.xml</LinkAddress><LinkTitle>NVS: config ssz</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:56 2008 PST
</Updated>
<Links>
</Links>
</Error>